The proposed hybrid method combines computationally efficient finite-element analysis (CE-FEA) with a new analytical formulation for eddy-current losses in the permanent magnets (PMs) of sine-wave current-regulated brushless synchronous motors. The CE-FEA only employs a reduced set of magnetostatic solutions yielding substantial reductions in the computational time, as compared with the conventional FEA. The 3-D end effects and the effect of pulsewidth-modulation switching harmonics are incorporated in the analytical calculations. The algorithms are applied to two fractional-slot concentrated-winding interior PM motors with different circumferential and axial PM block segmentation arrangements. The method is validated against 2-D and 3-D time-stepping FEA.