Dynamic modeling study reveals membrane relaxation dominates transient response times in fuel cell humidifiers, highlighting the need to incorporate polymer dynamics in system design.
This paper features a dynamic model for gas-to-gas membrane humidifiers based on first principles. The key novelty is the consideration of membrane relaxation in the dynamics. The model is validated under steady-state conditions against experimental data showing a deviation of less than 10 % for 46 % of the data points for Nafion® 211, for 77 % of the data points for Nafion® 212, and for 77 % of the data points for Nafion® 115. Three step responses are investigated using characteristic time scales. In all cases considered in this paper, the fluid-dynamic residence time has the lowest value (approximately 0.01 s) and the diffusive time constant (approximately 3 s) is in the same order of magnitude or one magnitude lower than the relaxation time constant (approximately 3 to 50 s). Finally, a step test for varying membrane thickness between 25.4 µm and 127 µm is conducted, yielding response times between 155 s and 211 s being dominated by relaxation. The findings highlight the importance of considering relaxation while modeling membrane humidifiers.
No takes yet. Share an insight, caveat, or question.
Kreitmeir et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: