Lots of motors have been being used in industry. Therefore many studies have been carried out about the failure diagnosis of motors. In this paper, a diagnosis of gear fault connected to a motor shaft is studied. The fault diagnosis is executed through the comparison of normal gear and abnormal gear. In the abnormal gearbox, a tooth of the intermediate gear is damaged. The measured FFT data are compared with the normal data and analyzed for q-axis current, noise and vibration. Fault gear was found by comparing the FFT with normal FFT. From these, the difference between the normal and abnormal states can be seen by the frequency characteristic analysis for the current as well as noise and vibration.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2016) studied this question.