Key result
Balloon dilatation of supravalvar aortic stenosis was feasible and provided good immediate results and sustained relief in three patients.
Why the study?
Does primary balloon dilatation improve the systolic pressure gradient and vessel diameter in patients with supravalvar aortic stenosis?
Case Report (n=3)
Does primary balloon dilatation improve the systolic pressure gradient and vessel diameter in patients with supravalvar aortic stenosis?
Balloon dilatation is a feasible procedure that can provide good immediate hemodynamic and anatomic results in patients with supravalvar aortic stenosis.
Answers are grounded in this paper and cite their sources.
Supports feasibility of balloon dilatation for supravalvar aortic stenosis; leaves open need for larger studies on durability.
Primary balloon dilatation of supravalvar aortic stenosis was attempted in three patients: a 20 year old woman, a seven month old boy, and a 12 year old girl. Balloon catheters (Mansfield) with diameters of 25 mm, 8 mm, and 15 mm were used in the three patients respectively. The systolic pressure gradient across the aortic narrowing decreased considerably and the diameter of the constricted area increased significantly. Balloon dilatation was feasible and provided good immediate results and sustained relief of supravalvar aortic stenosis in these three patients. However, a larger study is needed to establish the place of this procedure in treatment.
No takes yet. Share an insight, caveat, or question.
Jacob et al. (1993) conducted a case report in Supravalvar aortic stenosis (n=3). Balloon dilatation was evaluated on Systolic pressure gradient across the aortic narrowing and diameter of the constricted area. Balloon dilatation of supravalvar aortic stenosis was feasible and provided good immediate results and sustained relief in three patients.
Synapse has enriched 10 related papers. Consider them for comparative context: