Answers are grounded in this paper and cite their sources.
In statistical process control, the primary method used to monitor the number of nonconformities is the c-chart. The conventional c-chart is based on the assumption that the occurrence of nonconformities in samples is well modeled by a Poisson distribution. When the Poisson assumption is not met, the X-chart (individuals chart) is often used as an alternative charting scheme. In this article, we investigate the relative merits of the c-chart compared to the X-chart for the Katz family covering equi-, under-, and over-dispersed distributions relative to the Poisson distribution. The need to use an X-chart rather than a c-chart depends upon whether or not the ratio of the in-control variance to the in-control mean is close to unity. The X-chart, which incorporates the information on this ratio, can lead to significant improvements under certain circumstances. Both 3-sigma c- and X-charts fail to provide reliable information on the status of the process with a small in-control process mean when a downward mean shift occurs. In these cases, charts based on probability limits are much more appropriate.
No takes yet. Share an insight, caveat, or question.
Yue Fang (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: