Key result
Electronic queries combining ICD-9 codes and microbiology data identified infectious complications after CIED procedures with approximately 90% sensitivity and 80% specificity.
Why the study?
Does an automated surveillance tool using ICD-9 codes and microbiology data accurately identify infectious complications after CIED procedures in adults?
Cohort (n=6,097)
No
Does an automated surveillance tool using ICD-9 codes and microbiology data accurately identify infectious complications after CIED procedures in adults?
An automated surveillance strategy combining ICD-9 codes and microbiology data provides good sensitivity and specificity for detecting CIED infections, offering an efficient alternative to manual review.
May support automated CIED infection surveillance as an efficient alternative to manual review; leaves open prospective validation before routine use.
Background. The optimum approach for infectious complication surveillance for cardiac implantable electronic device (CIED) procedures is unclear. We created an automated surveillance tool for infectious complications after CIED procedures. Methods. Adults having CIED procedures between January 1, 2005 and December 31, 2011 at Duke University Hospital were identified retrospectively using International Classification of Diseases, 9th revision (ICD-9) procedure codes. Potential infections were identified with combinations of ICD-9 diagnosis codes and microbiology data for 365 days postprocedure. All microbiology-identified and a subset of ICD-9 code-identified possible cases, as well as a subset of procedures without microbiology or ICD-9 codes, were reviewed. Test performance characteristics for specific queries were calculated. Results. Overall, 6097 patients had 7137 procedures. Of these, 1686 procedures with potential infectious complications were identified: 174 by both ICD-9 code and microbiology, 14 only by microbiology, and 1498 only by ICD-9 criteria. We reviewed 558 potential cases, including all 188 microbiology-identified cases, 250 randomly selected ICD-9 cases, and 120 with neither. Overall, 65 unique infections were identified, including 5 of 250 reviewed cases identified only by ICD-9 codes. Queries that included microbiology data and ICD-9 code 996.61 had good overall test performance, with sensitivities of approximately 90% and specificities of approximately 80%. Queries with ICD-9 codes alone had poor specificity. Extrapolation of reviewed infectious rates to nonreviewed cases yields an estimated rate of infection of 1.3%. Conclusions. Electronic queries with combinations of ICD-9 codes and microbiologic data can be created and have good test performance characteristics for identifying likely infectious complications of CIED procedures.
No takes yet. Share an insight, caveat, or question.
Boggan et al. (2015) conducted a cohort in Cardiac implantable electronic device (CIED) procedures (n=6,097). Electronic queries combining ICD-9 codes and microbiology data vs. ICD-9 codes alone was evaluated on Test performance characteristics (sensitivity and specificity) for identifying infectious complications. Electronic queries combining ICD-9 codes and microbiology data identified infectious complications after CIED procedures with approximately 90% sensitivity and 80% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: