This is the authors' abstract. We don't add key points for this paper.
A novel tetraazamacrocycle fluorescent sensor (6-(1-(dimethylamino)-5-naphthalene sulfonyl)-3,6,9,15-tetraazabicyclo[9.3.1] pentadeca-1(15),11,13-triene, 1) has been designed and prepared, which can be utilized for selective and ratiometric sensing of Hg(2+) and bovine serum albumin (BSA) with two different responsive modes in aqueous solution at physiological pH (50 mM Tris-HCl, pH 7.6). Above 0.5 ppb Hg(2+) can be discerned by coordination with 1 and the emission color changes enable 1 to be applied to a fast Hg(2+) test paper assay. Sensor 1 has also been demonstrated to be easily cell-penetrable and applicable for Hg(2+) imaging in living cells. Imaging of BSA in the gel using SDS-PAGE (sodium dodecyl sulfate polyacrylamide gel electrophoresis) stained in the medium containing 1 verified that the binding of 1 and BSA was successful in the presence of nonprotein substances. The linear range of 1 towards BSA utilizing ratiometric fluorescent calibration via noncovalent interaction in solution is 0-100 μg mL(-1) with a detection limit of 1 μg mL(-1), and has been successfully employed to determine the albumin concentration in blood serum by means of ratiometric fluorescent measurements for the first time. Finally, sensor 1 behaves as a fluorescent molecular switch composed of triple logic gates upon chemical inputs of Hg(2+) and BSA, which potentially provides intelligent diagnostics for Hg(2+) contaminated serum on the nanoscale.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Wen et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: