Nephrotoxicity of radio-opaque contrast media (CM) is generally believed to involve toxic injury of proximal tubular cells. Measurement of urinary tubular enzyme excretion has been advocated as a sensitive marker of such toxic injury. It has been claimed that the new low-osmolality or nonionic CM reduce the incidence of nephrotoxicity but this remains uncertain. We studied 23 patients with normal renal function undergoing coronary angiography; patients were randomized into three groups receiving either diatrizoate (1,800 mmol/kg H2O), ioxaglate (600 mmol/kg H2O) or iohexol (850 mmol/kg H2O). Urinary excretion of a panel of enzymes increased significantly in all groups by 20 h (p less than 0.05 to less than 0.005). Alanine aminopeptidase excretion at 20 h was greater after the administration of high osmolality ionic CM than with the others but all three CM produced a similar pattern of enzyme excretion. No significant change in glomerular filtration rate was found in any group so the significance of the enzymuria remains uncertain.
No takes yet. Share an insight, caveat, or question.
Jevnikar et al. (2008) studied this question.