Key result
Multiple percutaneous closures of a post-infarct ventricular septal defect using Amplatzer devices failed to completely resolve the shunt, and the patient died on day 23.
Case Report (n=1)
No
This case highlights the extreme clinical challenges and potential for poor outcomes when attempting multiple percutaneous closures for post-infarct VSD in patients unfit for surgery.
Answers are grounded in this paper and cite their sources.
Emphasizes high mortality with repeated percutaneous closures in post-infarct VSD; leaves open optimal strategies for surgery-ineligible patients.
A 77-year-old lady developed a ventricular septal defect (VSD) 48 h after an anterior myocardial infarction. Echocardiography suggested an apical defect. Following two previous successful procedures in our centre, it was felt that a percutaneous approach to VSD closure should be taken, as the surgical view favoured a minimum 2-week pre-operative stabilization period with balloon pump in situ. She underwent an initial percutaneous VSD closure procedure 8 days post-infarct. Two defects were identified and closed with 24 mm and 16 mm post-infarct Amplatzer VSD devices, respectively. Her recovery was unfortunately complicated by chest sepsis and deteriorating renal function. Transthoracic echocardiogram confirmed persistent left-to-right flow, and invasive studies on day-17 demonstrated a residual 2:1 shunt. A further attempt at defect closure seemed the only option at this stage, as she was not fit for surgery. An additional defect was identified and successfully closed with an 18 mm device, but again without complete resolution of the shunt on ventriculography. It was hoped that this would settle with thrombosis and subsequent endothelialization of the devices, but sepsis and renal failure persisted, and she died on the 23rd day post-infarct.
No takes yet. Share an insight, caveat, or question.
Webb et al. (2006) conducted a case report in Ventricular septal defect post-myocardial infarction (n=1). Percutaneous VSD closure using Amplatzer devices was evaluated. Multiple percutaneous closures of a post-infarct ventricular septal defect using Amplatzer devices failed to completely resolve the shunt, and the patient died on day 23.