Key result
Capacitive touch screens accurately extract heart rate with a correlation slope near ~1.
Why the study?
Existing heart-rate sensing systems that trace light reflected from blood vessels require considerable power and space to be implemented in multi-functional mobile devices such as smart phones.
Does capacitive sensing using laterally interspaced top electrodes on a touch screen panel accurately measure heart rate compared to direct wrist pulse counting?
Does capacitive sensing using laterally interspaced top electrodes on a touch screen panel accurately measure heart rate compared to direct wrist pulse counting?
This engineering proof-of-concept demonstrates that standard capacitive touch screen panels can reliably measure human heart rate using laterally interspaced non-adjacent electrodes without requiring dedicated optical or ECG hardware.
Answers are grounded in this paper and cite their sources.
May enable touch-screen HR sensing without added hardware; leaves open clinical validation before adoption.
It is demonstrated that the heart-rate can be sensed capacitively on a touch screen panel (TSP) together with touch signals. The existing heart-rate sensing systems measure blood pulses by tracing the amount of light reflected from blood vessels during a number of cardiac cycles. This type of sensing system requires a considerable amount of power and space to be implemented in multi-functional mobile devices such as smart phones. It is found that the variation of the effective dielectric constant of finger stemming from the difference of systolic and diastolic blood flows can be measured with laterally interspaced top electrodes of TSP. The spacing between a pair of non-adjacent top electrodes turns out to be wide enough to distinguish heart-rate signals from noises. With the aid of fast Fourier transform, the heart-rate can be extracted reliably, which matches with the one obtained by actually counting heart beats on the wrist.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2020) studied Healthy human subjects (proof-of-concept heart-rate sensing). Capacitive heart-rate sensing on a touch screen panel (TSP) using laterally interspaced top electrodes with band-pass filtering (0.5-3.0 Hz) and fast Fourier transform (FFT) vs. Direct manual pulse counting on the wrist was evaluated on Extracted heart rate (beats per minute, bpm) and correlation with directly counted wrist heart rate (Correlation slope ~1). Capacitive touch screen panels with laterally interspaced top electrodes reliably extracted heart rates with a correlation slope approaching 1.