Key result
Color-duplex ultrasonography had a low sensitivity (39%; 95% CI 29-48) compared to computed tomography-aortography for detecting major aneurysm-related morphological abnormalities post-EVAR.
Why the study?
Color-duplex ultrasonography could be an alternative to computed tomography-aortography for lifelong surveillance after EVAR, but level 1 evidence was lacking.
Does color-duplex ultrasonography provide sufficient diagnostic accuracy compared to computed tomography-aortography for surveillance in post-EVAR patients?
Observational (n=539)
Mutually blinded
Yes
Does color-duplex ultrasonography provide sufficient diagnostic accuracy compared to computed tomography-aortography for surveillance in post-EVAR patients?
Color-duplex ultrasonography has low overall sensitivity for post-EVAR surveillance compared to CTA, though its performance improves for detecting abnormalities that require effective reintervention.
Answers are grounded in this paper and cite their sources.
Color-duplex ultrasonography lacks sufficient sensitivity for routine post-EVAR surveillance; leaves open its adjunctive role in select patients.
Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-related morphological abnormality requiring reintervention or an amendment to the follow-up policy was revealed by CTA. Database was locked on October 2, 2017. Our main outcome measures were sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratios of DUS against reference standard CTA. CIs are binomial 95% CI. Results This study recruited prospectively 659 post-EVAR patients of whom 539 (82%) were eligible for further analysis. Following the baseline inclusion visit, 940 additional follow-up visits were performed in the 539 patients. Major aneurysm-related morphological abnormalities were revealed by CTA in 103 patients (17.2/100 person-years [95% CI, 13.9-20.5]). DUS accurately identified 40 patients where a major aneurysm-related morphological abnormality was present (sensitivity, 39% [95% CI, 29-48]) and 403 of 436 patients with negative CTA (specificity, 92% [95% CI, 90-95]). The negative predictive value and positive predictive value of DUS were 92% (95% CI, 90-95) and 39% (95% CI, 27-50), respectively. The positive likelihood ratio was 4.87 (95% CI, 2.9-9.6). DUS sensitivity reached 73% (95% CI, 51-96) in patients requiring an effective reintervention. Conclusions DUS had an overall low sensitivity in the follow-up of patients after EVAR, but its performance improved meaningfully when the subset of patients requiring effective reinterventions was considered. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01230203.
No takes yet. Share an insight, caveat, or question.
Jean‐Baptiste et al. (2020) conducted an observational in Endovascular abdominal aortic aneurysm repair (EVAR) (n=539). Color-duplex ultrasonography (DUS) vs. Computed tomography-aortography (CTA) was evaluated on Detection of major aneurysm-related morphological abnormalities (Sensitivity 39%, 95% CI 29-48). Color-duplex ultrasonography had a low sensitivity (39%; 95% CI 29-48) compared to computed tomography-aortography for detecting major aneurysm-related morphological abnormalities post-EVAR.
Synapse has enriched 10 related papers. Consider them for comparative context: