Answers are grounded in this paper and cite their sources.
The operating point of conventional grid-tied photovoltaic (PV) arrays is controlled at the central inverter level, which leads to disproportionate power loss when an array is partially shaded. “Power optimizers,” electronic devices which perform power conversion and maximum power point tracking (MPPT) at the sub-array level, have been proposed to mitigate these losses. This work compares and analyzes the potential for recoverable power from these devices if they are used at different levels in a partially shaded array, including at the string, module, substring (bypass diode), or cell levels. Annual simulations are run varying climate, array size and configuration, and shade extent and pattern. In addition, power recovery potential with power optimizers is compared to that if bypass diodes were incorporated in the array at the cell level instead. Results show that potential for power recovery depends heavily on array configuration and shade properties, though module and cell level optimizers provide substantially more added benefit than those at the substring level. Cell-level bypass diodes also show good potential for increased energy capture.
No takes yet. Share an insight, caveat, or question.
Brandemuehl et al. (2011) studied this question.