Key result
Distal radial PCI using 7-Fr thin-walled sheaths achieves 100% success in ACS.
Why the study?
Does percutaneous coronary intervention via distal radial access using a 7-Fr hydrophilic thin-walled sheath improve PCI success rate and prevent access site complications in patients with acute coronary syndrome?
Does percutaneous coronary intervention via distal radial access using a 7-Fr hydrophilic thin-walled sheath improve PCI success rate and prevent access site complications in patients with acute coronary syndrome?
Answers are grounded in this paper and cite their sources.
Distal radial access using a 7-Fr hydrophilic coated thin-walled sheath is a highly feasible and safe option for complex PCI in patients with acute coronary syndrome.
We evaluated the feasibility and safety of the 7-Fr hydrophilic coated thin-walled sheath for distal radial access (DRA) - percutaneous coronary intervention (PCI). We prospectively collected data from 100 patients who underwent PCI via DRA with a 7-Fr hydrophilic thin-walled sheath at a single center in Korea between August 2021 and April 2024. Co-primary outcomes were PCI success rate and access site complications assessed by vascular ultrasound during hospitalization and at 1-month follow up. The mean age of study population was 65.9 years, and all patients presented acute coronary syndrome. DRA-PCI was successful in all patients. Of the 43 patients evaluated forearm radial artery with intravascular imaging after PCI, there were 2 cases of thrombus and 1 intimal dissection. Access site complications included 2 small hematomas and 1 hand edema. Vascular ultrasound performed the day after PCI showed no forearm radial artery occlusion (RAO) but 2 distal RAO cases without serious complications. At 1 month follow-up, 2 consistent and 1 new case of distal RAO were observed without hand dysfunction. The SEVEN-BOX trial showed that DRA using a 7-Fr hydrophilic coated thin-walled sheath could be a feasible and safe option for complex PCI.Clinical trial registration: https://www.clinicaltrials.gov . Unique identifier: NCT05006027.
No takes yet. Share an insight, caveat, or question.
Roh et al. (2025) studied acute coronary syndrome (n=100). 7-Fr hydrophilic coated thin-walled sheath was evaluated on PCI success rate and access site complications assessed by vascular ultrasound during hospitalization and at 1-month follow up. Percutaneous coronary intervention via distal radial access using a 7-Fr hydrophilic thin-walled sheath was successful in 100% of patients with acute coronary syndrome.