Key result
Use of a hydrophilic-coated radial sheath was associated with a 0.23% incidence of delayed inflammatory skin reactions at 28 days.
Why the study?
Does a hydrophilic-coated radial sheath cause delayed cutaneous inflammatory reactions in patients undergoing radial cardiac catheterisation?
Observational (n=431)
No
Does a hydrophilic-coated radial sheath cause delayed cutaneous inflammatory reactions in patients undergoing radial cardiac catheterisation?
The use of the Cook hydrophilic-coated radial sheath is safe, with a very low incidence (0.23%) of delayed inflammatory skin reactions.
Answers are grounded in this paper and cite their sources.
Very low reaction rates support safety of hydrophilic radial sheaths in practice; leaves open causality for randomized confirmation.
Objectives: To examine the efficacy and safety of a hydrophilic-coated radial sheath previously associated with inflammatory cutaneous reactions. Background: Hydrophilic sheaths have a role in reducing the observed incidence of radial artery spasm. Delayed cutaneous inflammatory reactions have been reported following the use of some hydrophilic coated sheaths. Methods: SACRED (Systematic Assessment of the Cook Radial ShEath Device) was a prospective, single-centre registry study. The primary outcome measure was the observed incidence of cutaneous reaction to 28 days. Secondary outcome measures included: procedural success rate with the study sheath; rate of use of intra-arterial vasodilator agents; and the incidence of adverse events related to the access site during the index admission. A total of 431 patients were recruited. Results: Follow-up was completed in 429/433 (99.1%) radial sites instrumented with the study sheath. A single incidence of a delayed inflammatory skin reaction was observed (1/429; 0.23%) (95% confidence interval 0–0.68%). Failure to access the radial artery occurred in 19/446 attempts (4.3%). Overall, accessrelated intra-arterial vasodilator use was low at 83/433 (19.2%); routine, prophylactic use accounted for 70/83 (84.3%). The majority of operators were non-routine users but gave vasodilators in response to radial artery spasm in 13/363 (3.6%) of cases. Access site-related complications were minor and occurred in 33/446 (7.4%) of radial sites. Before discharge from the index procedure, radial artery occlusion was observed in 15/412 (3.6%). Conclusions: A single, self-limiting lesion suggested granuloma but without histological confirmation. Access success rates were comparable with other studies but with non-routine use of vasodilators. Radial artery occlusion at discharge was associated with older age, lower body weight and a failure to anticoagulate.
No takes yet. Share an insight, caveat, or question.
Mars et al. (2017) conducted an observational in Radial cardiac catheterisation (n=431). Hydrophilic-coated radial sheath (Cook Radial ShEath Device) was evaluated on Observed incidence of cutaneous reaction to 28 days (95% CI 0-0.68). Use of a hydrophilic-coated radial sheath was associated with a 0.23% incidence of delayed inflammatory skin reactions at 28 days.