In this paper, we utilize micro-Raman spectroscopy to measure temperature and stress in state-of-the-art AlGaN/GaN HEMTs. A rigorous discussion on the physical accuracy, precision, and precautions for diverse Raman thermometry methods is developed. Thermometry techniques utilizing shifts in a single Raman Stokes peak position underpredict the channel temperature due to induction of operational thermoelastic stress in operating devices. Utilizing the change in phonon linewidth by employing a proper reference condition gives true temperature results. Making use of frequency shifts in both theE2(high) andA1(LO) phonon modes offers accurate and time-efficient means to determine the state of temperature and thermal stress in operating AlGaN/GaN HEMTs presuming that linear relations between phonon frequencies and temperature/stress are well determined. Useful applications of this method such as monitoring stress in GaN wafers between fabrication steps and Raman thermography on AlGaN/GaN HEMTs are demonstrated.
No takes yet. Share an insight, caveat, or question.
Choi et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: