Answers are grounded in this paper and cite their sources.
The paper is an attempt to assess the power-carrying capacity, within the limits of electrical breakdown, of various forms of metal waveguide. The discussion relates to wave modes commonly used inside tubes of rectangular and circular cross-section, or alternatively outside a solid wire.It is assumed that the guides are surrounded by air dielectric, of uniform cross-section, free of obstacles and discontinuities. The results show that for hollow guides the H modes are inferior to the E modes in respect of power-carrying capacity.The solid wire guide supporting a surface wave has an astonishing performance considering the cross-section of the conductor concerned, and for millimetre wavelengths particularly this form has much to recommend it.
No takes yet. Share an insight, caveat, or question.
H.M. Barlow (1952) studied this question.