Key result
B-Flow ultrasound matches standard imaging for endoleak detection with ~88% CTA agreement during EVAR surveillance.
Why the study?
CTA and CEUS are reference standards for endoleak surveillance after EVAR, but both require contrast enhancement and CTA exposes patients to ionizing radiation. The performance of B-Flow coded-excitation ultrasound for endoleak detection compared with CEUS, CTA, and DUS needed evaluation.
Does B-Flow coded-excitation ultrasound accurately detect and classify endoleaks compared to CEUS, CTA, and DUS in patients undergoing surveillance after endovascular aortic repair (EVAR)?
Cohort (n=34)
No
Does B-Flow coded-excitation ultrasound accurately detect and classify endoleaks compared to CEUS, CTA, and DUS in patients undergoing surveillance after endovascular aortic repair (EVAR)?
Answers are grounded in this paper and cite their sources.
B-Flow coded-excitation ultrasound provides high agreement with CTA and CEUS for post-EVAR endoleak surveillance and 100% accuracy for clinically actionable endoleaks without requiring intravenous contrast or ionizing radiation.
Endoleaks are the most common complication after endovascular aortic repair (EVAR). Their correct identification is one of the main objectives of surveillance protocols after EVAR. So far, computed tomography angiography (CTA), contrast-enhanced (CEUS) and Duplex ultrasound (DUS), as well as magnetic resonance angiography, have been investigated for their ability to detect endoleaks. In general, all technologies have distinct benefits and disadvantages, with CTA and CEUS emerging as the reference standard for surveillance after EVAR. However, they are both contrast-enhancer-dependent, and CTA additionally exposes patients to ionizing radiation. In the present study, we investigated B-Flow, a type of coded-excitation ultrasound that was specifically designed to optimize the visualization of blood flow, for its ability to detect endoleaks, and compared its performance to CEUS, CTA, and DUS. In total, 34 patients were included in the analysis that accumulated in 43 distinct B-Flow investigations. They underwent a total of 132 imaging investigations. Agreement between B-Flow and other imaging modalities was high (>80.0%), while inter-method reliability can be interpreted as good. However, with B-Flow, six and one endoleaks would have been missed compared to CEUS and CTA, respectively. Regarding endoleak classification, all metrics were lower but retained an adequate level of comparison. In a subset of patients requiring intervention, B-Flow had 100% accuracy regarding both endoleak detection and classification. Ultrasonography enables endoleak detection and classification without the need for pharmaceutical contrast enhancement or radiation. Ultrasound coded-excitation imaging in the application of B-Flow could further simplify surveillance after EVAR by offering adequate accuracy without requiring intravenous contrast enhancement. Our findings may promote subsequent investigations of coded-excitation imaging for endoleak detection and classification in the surveillance after EVAR.
No takes yet. Share an insight, caveat, or question.
Hofmann et al. (2023) conducted a cohort in Abdominal aortic aneurysm treated with endovascular aortic repair (EVAR) (n=34). B-Flow coded-excitation ultrasound vs. Contrast-enhanced ultrasound (CEUS), computed tomography angiography (CTA), and Duplex ultrasound (DUS) was evaluated on Endoleak detection agreement between B-Flow and established imaging modalities (CEUS, CTA, DUS). B-Flow ultrasound demonstrated high agreement for endoleak detection with CEUS, CTA, and DUS, with 100% accuracy in patients requiring secondary intervention.