Answers are grounded in this paper and cite their sources.
This paper describes a complete digitally controlled dc-dc buck converter performed by field-programmable gate array (FPGA) circuitry. The voltage and current-mode control is based on a voltage control oscillator (VCO) performed measurements regarding output-voltage and inductor current, respectively. This measurement principle also uses digital-counters (digital-integrators) in order to obtain integral values for the output-voltage and inductor current. In analog current-mode control, the instantaneous inductor current-value-measurement is used for the switching action. When the VCO is used for the inductor current measurement, the integral is measured during the switching-on time set as an observation interval and the switching action occurs based on this measurement. Such a principle enables full digitalization of the voltage- and current-control loop and also the used measurement principle is capable of rejecting the switching disturbances during current and voltage measurements. All the tasks for current and voltage control were implemented within the FPGA. The algorithm was verified by simulation and experimentation at a switching-frequency of 25kHz.
No takes yet. Share an insight, caveat, or question.
Truntič et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: