The development of dissolution testing conditions for drugs exhibiting low aqueous solubility like candesartan cilexetil is a challenging task for pharmaceutical scientists and regulatory organizations. The purpose of this study was to evaluate the discriminatory power of the dissolution testing medium specified by USP, which is 0.35% polysorbate 20 in 0.05 M potassium dihydrogen phosphate pH 6.5, for 4-, 8-, and 16-mg candesartan cilexetil tablets. We analyzed the drug release pattern and similarity factors of some generic products marketed in Egypt in comparison to the reference product (Atacand). It was found that, despite the ability of the method to effectively discriminate between the different 16-mg tablets, it failed to demonstrate any discriminative ability of the 4-and 8-mg doses without any formula alteration. Therefore, an attempt was made to develop a new medium for the 4-and 8-mg doses that could provide a reasonable sink condition and discriminatory power by reducing the percentage of polysorbate 20 in the medium from 0.35% to 0.1%. The alternative dissolution medium demonstrated an acceptable sink condition and satisfactory discrimination power between the different marketed products, suggesting the use of this medium (0.1% polysorbate 20 in 0.05 M potassium dihydrogen phosphate, pH 6.5) to aid in product development and testing of finished product quality.