Key result
Isokinetic, isometric, and isotonic knee muscle strength measurements demonstrated high test-retest reliability and small measurement errors in persons with late effects of polio.
Observational (n=30)
No
Knee muscle strength can be measured reliably in persons with late effects of polio to detect real changes for a group, but values may be too high to detect small short-term changes in single individuals.
Answers are grounded in this paper and cite their sources.
Supports reliable group-level knee strength monitoring in late polio; leaves open detection of small individual changes.
OBJECTIVE: To assess the reliability of knee extensor and flexor muscle strength measurements in persons with late effects of polio. DESIGN: A test-retest reliability study. SUBJECTS: Thirty men and women (mean age 63 (standard deviation 6.4) years) with verified late effects of polio. METHODS: Knee extensor and flexor muscle strength in both lower limbs were measured twice 7 days apart using a Biodex dynamometer (isokinetic concentric contractions at 60 degrees /sec and isometric contractions with knee flexion angle 90 degrees) and a Leg Extension/Curl Rehab exercise machine with pneumatic resistance (HUR) (isotonic contractions). Reliability was assessed with the intraclass correlation coefficient (ICC1,1), the mean difference between the test sessions (d) together with the 95% confidence intervals for d, the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%) and Bland-Altman graphs. RESULTS: Test-retest agreements were high, (ICC1,1 0.93-0.99) and measurement errors generally small. The SEM% was 4-14% and the SRD% 11-39%, with the highest values for the isokinetic measurements. CONCLUSION: Knee muscle strength can be measured reliably and can be used to detect real changes after an intervention for a group of persons with late effects of polio, whereas the values may be too high for single individuals or to detect smaller short-term changes over time for a group of individuals.
No takes yet. Share an insight, caveat, or question.
Flansbjer et al. (2010) conducted an observational in Late effects of polio (n=30). Knee extensor and flexor muscle strength measurements vs. Test session 1 vs Test session 2 was evaluated on Test-retest reliability (Intraclass correlation coefficient) (ICC 0.93-0.99). Isokinetic, isometric, and isotonic knee muscle strength measurements demonstrated high test-retest reliability and small measurement errors in persons with late effects of polio.
Synapse has enriched 10 related papers. Consider them for comparative context: