The behaviour of a continuous, steel-concrete composite box girder bridge was monitored during construction of the concrete deck and during the first three years of operation. It was observed that cracking developed in the deck which was attributed to the temperature developed in the deck shortly after casting, the sequence of casting, the shrinkage of the deck concrete, and the rapid heating of the steel boxes exposed to direct sunlight. It was also found that the strain distributions across the depth and the width of the steel boxes are more or less linear. This beam theory can be applied with confidence for the design of this type of structure.
No takes yet. Share an insight, caveat, or question.
Dilger et al. (1981) studied this question.