Key result
Internal tocography using intrauterine catheters did not significantly improve obstetric outcomes, including duration of labour or operative deliveries, compared to external tocography.
Why the study?
Does internal tocography improve obstetric outcomes compared to external tocography in women undergoing induced labour?
RCT (n=239)
randomized
Does internal tocography improve obstetric outcomes compared to external tocography in women undergoing induced labour?
Internal tocography does not improve obstetric or neonatal outcomes compared to external tocography during induction of labour.
Answers are grounded in this paper and cite their sources.
External tocography suffices for induced labour; challenges routine internal catheter use in obstetrics.
A prospective randomized study was undertaken to evaluate the benefit of intrauterine catheters in induced labour. Two hundred and thirty nine women who had induced labour were studied. The patients in one group had intrauterine catheters inserted and oxytocin was titrated to achieve the 75th percentile of uterine activity observed in spontaneous normal labour according to parity. Contractions were assessed by external tocography in the other group and oxytocin was titrated to achieve 6 to 7 contractions per 15 minutes each lasting > 40 seconds. Mean maximum dose of oxytocin, mode of delivery, Apgar score < 7 at 5 minutes, cord arterial blood pH < 7.15 and admission to neonatal intensive care unit did not differ significantly in the 2 groups. In conclusion, women who had intrauterine catheters did not have a shorter duration of labour, lower dose of oxytocin, fewer operative deliveries or fewer babies in poor condition at birth compared with those who had external tocography in induced labour.
No takes yet. Share an insight, caveat, or question.
Chia et al. (1993) conducted an RCT in Induced labour (n=239). Internal tocography (intrauterine catheters) vs. External tocography was evaluated on Mean maximum dose of oxytocin, mode of delivery, Apgar score < 7 at 5 minutes, cord arterial blood pH < 7.15 and admission to neonatal intensive care unit. Internal tocography using intrauterine catheters did not significantly improve obstetric outcomes, including duration of labour or operative deliveries, compared to external tocography.
Synapse has enriched 10 related papers. Consider them for comparative context: