Key result
Noninvasive auricular densitometry showed no significant difference compared to direct blood sampling for measuring hepatic perfusion in children during and after cardiopulmonary bypass.
Why the study?
Does noninvasive auricular densitometry accurately measure hepatic perfusion compared to direct blood sampling in children undergoing cardiac surgery?
Observational (n=16)
Does noninvasive auricular densitometry accurately measure hepatic perfusion compared to direct blood sampling in children undergoing cardiac surgery?
Noninvasive auricular densitometry provides a reliable assessment of hepatic perfusion in children undergoing cardiac surgery, offering an alternative to invasive blood sampling.
Answers are grounded in this paper and cite their sources.
May support noninvasive auricular densitometry for hepatic perfusion in pediatric CPB; hypothesis-generating and requires prospective validation.
The clinical measurement of hepatic perfusion is complicated by a dual blood supply and the invasive nature of the majority of techniques available. The aim of this study was to validate indocyanine green clearance and noninvasive auricular densitometry as a measure of hepatic perfusion in the context of paediatric cardiac surgery. The effects of different dye concentrations on densitometer recording were assessed in vitro and found to have a linear relationship. Similarly, variations in haematocrit, within the range 21-47%, also had little effect on accuracy. Comparison of densitometry and direct blood sampling with plasma spectrophotometry in six postoperative, normothermic children showed no significant difference between the noninvasive and invasive techniques (r = 0.968; p > 0.05, t-test). Comparison in 10 hypothermic children during cardiopulmonary bypass also showed no significant difference between the two methods, provided that no further cooling or rewarming took place (r = 0.83; p > 0.05, Wilcoxon test). Noninvasive auricular densitometry can, therefore, provide a reliable assessment of hepatic perfusion in children undergoing cardiac surgery.
No takes yet. Share an insight, caveat, or question.
Mitchell et al. (1995) conducted an observational in Paediatric cardiac surgery (n=16). Noninvasive auricular densitometry for indocyanine green clearance vs. Direct blood sampling with plasma spectrophotometry was evaluated on Difference between noninvasive and invasive techniques for measuring hepatic perfusion (r = 0.968 (postoperative); r = 0.83 (during bypass), p=> 0.05). Noninvasive auricular densitometry showed no significant difference compared to direct blood sampling for measuring hepatic perfusion in children during and after cardiopulmonary bypass.
Synapse has enriched 10 related papers. Consider them for comparative context: