Key result
Short-duration DAPT after drug-eluting stent implantation showed no significant difference in stent thrombosis compared to long-duration DAPT (OR 1.59; 95% CI 0.77-3.27).
Why the study?
Does long duration DAPT compared to short duration DAPT reduce stent thrombosis in patients after drug-eluting stent implantation?
Meta-Analysis (n=19,760)
Does long duration DAPT compared to short duration DAPT reduce stent thrombosis in patients after drug-eluting stent implantation?
In patients with drug-eluting stents, short-duration DAPT reduces major bleeding but increases the risk of myocardial infarction compared to long-duration DAPT at 2 or more years of follow-up.
Short DAPT yields similar stent thrombosis rates after DES; challenges prolonged regimens and supports bleeding-risk-guided duration.
OBJECTIVE: To evaluate the long term efficacy and safety of long duration DAPT (L-DAPT) compared to short duration DAPT (S-DAPT) after drug-eluting stent (DES) implantation. METHODS: We searched Medline, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) to identify randomized controlled trials (RCTs) assessing the clinical impact of L-DAPT versus S-DAPT after DES and have mean follow up period of at least 2 years or longer. Primary end point was stent thrombosis (ST). Secondary endpoints were all-cause mortality, cardiac mortality, myocardial infarction (MI), target vessel revascularization (TVR), thrombolysis in myocardial infarction (TIMI) major bleeding and stroke. Event rates were compared using a random effects model. RESULTS: We identified five RCTs in which 19,760 patients were randomized to S-DAPT (N = 9,810) and L-DAPT (n = 9,950), respectively. Compared with L-DAPT, S-DAPT was associated with higher rate of MI (odds ratio [OR] 1.48, 95% confidence interval [CI] [1.04, 2.10]). There were no significant differences between S-DAPT and L-DAPT in terms of all cause mortality, cardiac mortality, ST, TVR or stroke (OR 0.90, 95% CI [0.73, 1.12]; OR 1.02, 95% CI [0.80, 1.30]; OR 1.59, 95% CI [0.77, 3.27]; OR 0.87 95% CI [0.67, 1.14]; and OR 1.08 95% CI [0.81, 1.46], respectively). However, rate of TIMI major bleeding was significantly lower with S-DAPT compared to L-DAPT (OR 0.64, 95% CI [0.41, 0.99]). CONCLUSIONS: In the present analysis of RCTs with longer follow up (2 years or longer), S-DAPT compared with L-DAPT, was associated with higher rate of MI and lower rate of major bleeding without any significant difference in the rates of all cause mortality, cardiac mortality, ST, TVR, and stroke.
No takes yet. Share an insight, caveat, or question.
Sharma et al. (2017) conducted a meta-analysis in Drug-eluting stent (DES) implantation (n=19,760). Short duration DAPT (S-DAPT) vs. Long duration DAPT (L-DAPT) was evaluated on Stent thrombosis (ST) (OR 1.59, 95% CI 0.77-3.27). Short-duration DAPT after drug-eluting stent implantation showed no significant difference in stent thrombosis compared to long-duration DAPT (OR 1.59; 95% CI 0.77-3.27).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: