Answers are grounded in this paper and cite their sources.
PURPOSE: This study was conducted to investigate one-piece narrow-diameter implants installed in maxillary lateral and mandibular incisor sites using immediate nonfunctional loading. MATERIALS AND METHODS: In this 10-year clinical trial study, 42 narrow-diameter (3.0-mm) one-piece implants for 35 patients were inserted. Clinical and radiographic measurements were recorded in 10 years and analyzed statistically using t test. RESULTS: A total of 26 patients (20 females and 6 males) with 30 implants were available for the 10-year follow-up. The 10-year implant survival rate was 100%. A statistically significant mean marginal bone loss was observed between 12 months and 10 years (0.18 ± 0.29 mm). The mean pocket depth increase was statistically significant (0.68 ± 0.83 mm). No bleeding on probing was observed around 90% of the implants. Full-mouth plaque index was registered at 20% of the implants. CONCLUSION: The results obtained in this analysis suggest that modest marginal bone loss was observed around the implants. One-piece narrow-diameter implants (Maximus 3.0; BioHorizons) can predictably restore missing maxillary lateral incisors and mandibular incisors in cases of careful patient selection.
No takes yet. Share an insight, caveat, or question.
Kadkhodazadeh et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: