Key result
In patients undergoing CIED procedures, revision, upgrading, or reimplantation was strongly associated with an increased risk of CIED infection (OR 4.08; 95% CI 1.38-12.08).
Why the study?
The incidence of infections associated with cardiac implantable electronic devices and patient outcomes are not fully known.
What are the incidence and predictors of CIED infections and all-cause death in patients undergoing CIED procedures?
Cohort (n=2,675)
Yes
What are the incidence and predictors of CIED infections and all-cause death in patients undergoing CIED procedures?
Answers are grounded in this paper and cite their sources.
In a nationwide Italian registry, CIED infections occurred in 1.1% of patients at 12 months, with device revision/upgrading and diabetes identified as significant predictors.
Background: The incidence of infections associated with cardiac implantable electronic devices (CIEDs) and patient outcomes are not fully known. Aim: To provide a contemporary assessment of the risk of CIEDs infection and associated clinical outcomes. Methods: In Italy, 18 centres enrolled all consecutive patients undergoing a CIED procedure and entered a 12-months follow-up. CIED infections, as well as a composite clinical event of infection or all-cause death were recorded. Results: A total of 2675 patients (64.3% male, age 78 (70–84)) were enrolled. During follow up 28 (1.1%) CIED infections and 132 (5%) deaths, with 152 (5.7%) composite clinical events were observed. At a multivariate analysis, the type of procedure (revision/upgrading/reimplantation) (OR: 4.08, 95% CI: 1.38–12.08) and diabetes (OR: 2.22, 95% CI: 1.02–4.84) were found as main clinical factors associated to CIED infection. Both the PADIT score and the RI-AIAC Infection score were significantly associated with CIED infections, with the RI-AIAC infection score showing the strongest association (OR: 2.38, 95% CI: 1.60–3.55 for each point), with a c-index = 0.64 (0.52–0.75), p = 0.015. Regarding the occurrence of composite clinical events, the Kolek score, the Shariff score and the RI-AIAC Event score all predicted the outcome, with an AUC for the RI-AIAC Event score equal to 0.67 (0.63−0.71) p < 0.001. Conclusions: In this Italian nationwide cohort of patients, while the incidence of CIED infections was substantially low, the rate of the composite clinical outcome of infection or all-cause death was quite high and associated with several clinical factors depicting a more impaired clinical status.
No takes yet. Share an insight, caveat, or question.
Boriani et al. (2022) conducted a cohort in Cardiac implantable electronic device (CIED) procedures (n=2,675). Revision, upgrading, or reimplantation of CIED was evaluated on CIED infection (OR 4.08, 95% CI 1.38-12.08). In patients undergoing CIED procedures, revision, upgrading, or reimplantation was strongly associated with an increased risk of CIED infection (OR 4.08; 95% CI 1.38-12.08).
Synapse has enriched 10 related papers. Consider them for comparative context: