Answers are grounded in this paper and cite their sources.
This study provides a comprehensive evaluation of the effectiveness of 280 nm UV LEDs in enhancing chlorine disinfection in natural water sources. The results of this work indicate sequential treatments (UV‐chlorine and chlorine‐UV) further enhanced the disinfection efficiency of T1 in natural waters, especially at higher UV doses, such as 40 mJ cm −2 . The log reduction value for the chlorine‐UV sequence reached 6.65, slightly higher than the 6.29 for the UV‐chlorine sequence, suggesting that sequencing influences disinfection efficacy at higher fluences. UV LED‐enhanced chlorine disinfection did not significantly alter concentrations of THMs and HAAs. Overall, the findings of this study open new avenues for the application of UV LEDs in drinking water disinfection, demonstrating their potential as an alternative to traditional disinfection methods. Future research should further explore the effects of UV‐chlorine combined treatments under different water quality conditions to optimize disinfection processes and provide theoretical support for innovation in water treatment technologies.
No takes yet. Share an insight, caveat, or question.
A 2025 study studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: