Answers are grounded in this paper and cite their sources.
Free radicals of myoglobins were measured at room temperature with an ESR spectrometer equipped with a flow apparatus. When horse heart MetMb was mixed with an equimolar amount of ethyl hydroperoxide (EtOOH), a well resolved ESR spectrum with 6 lines and a shoulder was observed. It reached a maximum in a few seconds and decayed with a half-life of about 10 s when the final concentrations of MetMb and EtOOH were 200 microM. This decay rate was the same at a MetMb concentration of 50 microM. The maximum molar radical concentration amounted to about half of the total myoglobin. In the case of sperm whale myoglobin, a similar 6-line spectrum reached a maximum in 1 s and decayed with a half-life of a few seconds. In this case, however, a small and poorly resolved doublet spectrum remained, the half-life of which was about 8 min. An effect of O2 on the signal decay was evident for horse heart myoglobin, but not for sperm whale myoglobin.
No takes yet. Share an insight, caveat, or question.
Harada et al. (1987) studied this question.