Answers are grounded in this paper and cite their sources.
A microwave power limiter with an H-type slot structure is proposed as a waveguide structure that blocks high-power microwaves through plasma discharge. At an operating frequency of 5.75 GHz, the electric field is concentrated in the discharging electrode gap; when high power is applied, the plasma limiter discharges, and low power is transmitted. By contrast, when low power is applied, it is transmitted without loss. An H-type resonance structure was used to increase the electric field concentration and selectivity within the waveguide. At 5.75 GHz, the insertion loss of the H-type slot structure was 1.85 dB. The electric field concentration increased to 49492 V/m, and the 3 dB bandwidth was 535 MHz. In addition, the plasma discharge onset level in the xenon gas was lower because of the electrostatic potential. When an electrostatic potential of 300 V was applied, the plasma discharge onset level decreased from 310 to 180 W.
No takes yet. Share an insight, caveat, or question.
Park et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: