Recent studies have highlighted potential torsional stability risks in grid-forming (GFM) controlled wind turbine (WTs). While most research focuses on the active power control channel, the influence of reactive power control (RPC) is rarely concerned. To address this gap, this work aims to develop insights into the impact of RPC on the torsional stability of GFM-controlled DFIG WTs. Firstly, a linearized model is built to decompose the drivetrain's interaction effects with the mechanical/electrical subsystems. By incorporating RPC, the incremental electrical damping for the torsional mode is then analytically derived using the damping torque analysis method. Subsequently, various RPC configurations and gain settings are comprehensively examined across a spectrum of wind speeds and loading conditions. The results demonstrate the significant damping effect of RPC on torsional oscillations. Accordingly, a phase compensation strategy through RPC arm is proposed to enhance torsional stability. Finally, hardware-in-the-loop (HIL) simulation studies are carried out to validate the theoretical outcomes.