Key result
A serum albumin level < 3.8 g/dL was associated with a higher risk of atrial fibrillation recurrence following cryoballoon PVI ablation (OR 5.422; 95% CI 1.134-25.910; P<0.001).
Why the study?
Atrial fibrillation recurrence after pulmonary vein isolation ablation is clinically significant, making the identification of risk factors important.
Do lower serum albumin levels predict atrial fibrillation recurrence in patients undergoing cryoballoon pulmonary vein isolation?
Cohort (n=126)
No
Do lower serum albumin levels predict atrial fibrillation recurrence in patients undergoing cryoballoon pulmonary vein isolation?
Lower serum albumin levels (<3.8 g/dL) serve as a strong independent prognostic marker for atrial fibrillation recurrence following cryoballoon pulmonary vein isolation.
Lower SA may be associated with AF recurrence after cryoballoon PVI; leaves open its value for risk stratification.
Introduction: Atrial fibrillation (AF) recurrence following pulmonary vein isolation (PVI) ablation has clinical significance. Identifying risk factors for AF recurrence is important. We investigated serum albumin (SA) levels (g/dL) as a prognostic factor for the recurrence of AF following cryoballoon PVI ablation. Methods: We included patients who underwent cryoballoon PVI ablation at our institution between the years 2013 and 2018. The primary outcome was recurrence of AF during follow up. Results: Our cohort consisted of 126 patients (67% males, mean age 61.8 ± 10.0 years). The pattern of AF amongst the cohort was paroxysmal in 62.5%, persistent in 25.4%, and longstanding persistent in 6.3%. Those with lower SA levels had a mean AF duration significantly less than those with higher SA levels (2.81 years, 7.34 years, and 6.37 years for SA levels of <3.8, 3.8−4.1, and ≥4.1, respectively; p = 0.003). Patients with lower SA levels were significantly more likely to have had more previous cardioversions and a larger left atrial area and volume. The mean follow-up was 380 days, in which the AF recurrence rate was 20.6%. Patients with lower SA level had significantly more AF recurrences (47.4%, 16.7%, and 2.2% for SA levels of <3.8, 3.8−4.1, and ≥4.1, respectively; p < 0.001). Upon multivariate analysis, an SA level < 3.8 was associated with a higher risk of AF recurrence (OR = 5.422 95% CI 1.134; 25.910; p < 0.001). Conclusion: SA levels were found to be a strong independent marker for AF recurrence following PVI ablation.
No takes yet. Share an insight, caveat, or question.
Pravda et al. (2022) conducted a cohort in Atrial fibrillation (n=126). Serum albumin level < 3.8 g/dL vs. Serum albumin levels ≥ 3.8 g/dL was evaluated on Recurrence of AF during follow up (OR 5.422, 95% CI 1.134-25.910, p=<0.001). A serum albumin level < 3.8 g/dL was associated with a higher risk of atrial fibrillation recurrence following cryoballoon PVI ablation (OR 5.422; 95% CI 1.134-25.910; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: