Key result
Transcatheter aortic valve implantation significantly improved 4-dimensional echocardiographic global area strain from -25.6% to -28.0% at 6 months in patients with severe aortic stenosis and preserved ejection fraction.
Why the study?
Although LV function after transaortic valve implantation has been examined, 4-dimensional echocardiographic parameters of myocardial deformation have not been extensively studied, especially in patients with preserved ejection fraction aortic stenosis.
Does transcatheter aortic valve implantation improve left ventricular deformation parameters measured by 4-dimensional echocardiography in patients with severe aortic stenosis and preserved ejection fraction?
Cohort (n=60)
Single-blind
No
Does transcatheter aortic valve implantation improve left ventricular deformation parameters measured by 4-dimensional echocardiography in patients with severe aortic stenosis and preserved ejection fraction?
Answers are grounded in this paper and cite their sources.
Transcatheter aortic valve implantation significantly improves left ventricular deformation parameters, including global area strain and global longitudinal strain, in patients with severe aortic stenosis and preserved ejection fraction at 6 months.
OBJECTIVE: Beneficial effects of transaortic valve implantation on left ventricular hemodynamics and prognosis of patients have been demonstrated. Although left ventricular systolic and diastolic function following transaortic valve implantation procedure have been examined in previous studies, 4-dimensional echocardiographic parameters have not been extensively studied, especially in patients with preserved ejection fraction aortic stenosis. In our study, we planned to evaluate the effect of transaortic valve implantation on myocardial deformation using 4-dimensional echocardiography. METHODS: A total of 60 consecutive patients who underwent transaortic valve implantation for severe aortic stenosis with preserved ejection fraction were prospectively enrolled in the study. Standard 2-dimensional echocardiography and 4-dimensional echocardiography were performed in all patients before and 6 months after the transaortic valve implantation procedure. RESULTS: Six months after valve implantation, significant improvement was observed in global longitudinal strain (P < 0.001), spherical circumferential strain (P = 0.022), global radial strain (P = 0.008), and global area strain (P < 0.001). In the regression analysis, global area strain and absence of diabetes mellitus were determined as independent predictors to show a 10% increase in the left ventricular ejection fraction. CONCLUSIONS: In patients with preserved ejection fraction who underwent transaortic valve implantation, left ventricle deformation parameters have improved after 6 months, especially by using 4-dimensional echocardiography. The use of 4-dimensional echocardiography should be more common in daily practice.
No takes yet. Share an insight, caveat, or question.
Adil Bayramoğlu (2023) conducted a cohort in Severe aortic stenosis with preserved ejection fraction (n=60). Transcatheter Aortic Valve Implantation (TAVI) vs. Baseline was evaluated on Global area strain (GAS) (p=<0.001). Transcatheter aortic valve implantation significantly improved 4-dimensional echocardiographic global area strain from -25.6% to -28.0% at 6 months in patients with severe aortic stenosis and preserved ejection fraction.
Synapse has enriched 10 related papers. Consider them for comparative context: