We performed a prospective randomized study comparing fixation with biodegradable polyglycolic acid (PGA) rods (n 15) or screws (n 17) in 32 selected displaced supination-eversion fractures. Immediate postoperative weight bearing in a walking cast was encouraged. An exact reconstruction of the ankle mortise was achieved in 26/32 ankles. Roentgen stereophotogrammetric analysis (RSA) revealed rather small movements in the ankle mortise during fracture healing. A better stability was achieved by using screws. After 6 months the clinical results did not differ. One case of sinus formation and one with local effusion occurred; both healed without impairing the clinical result. To compare the results with a nondegradable osteosynthesis technique, a reference group of supination-eversion fractures previously operated on with cerclage-wires, staples and pins was used. RSA showed better fracture stability with nondegradable fixation. The clinical results, however, did not differ.
No takes yet. Share an insight, caveat, or question.
Ahl et al. (1994) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: