Key result
Boosted decision tree model improves AAA repair prediction accuracy to ~95% over logistic regression.
Why the study?
Diameter-based criteria for abdominal aortic aneurysm repair have limitations, and machine learning models incorporating clinical, biomechanical, and morphological data often lack clinical interpretability.
Does an XGBoost ensemble decision tree model with SHAP values improve predictive accuracy for abdominal aortic aneurysm repair outcomes compared to logistic regression while maintaining explainability?
Observational (n=512)
No
Does an XGBoost ensemble decision tree model with SHAP values improve predictive accuracy for abdominal aortic aneurysm repair outcomes compared to logistic regression while maintaining explainability?
Answers are grounded in this paper and cite their sources.
Integrating clinical, biomechanical, and morphological data into an XGBoost ensemble machine learning model improves predictive accuracy for AAA repair outcomes over logistic regression, while SHAP values preserve clinical explainability.
Background An abdominal aortic aneurysm (AAA) is an irreversible dilation of the terminal aorta, posing significant rupture risks. Current guidelines for surgical intervention rely on aneurysm diameter thresholds (5.0 cm for women, 5.5 cm for men). However, ruptures frequently occur below these thresholds, highlighting limitations in diameter-based approaches. Machine learning (ML) techniques that integrate clinical, biomechanical, and morphological data may enhance predictive accuracy, but can suffer from limited interpretability due to their inherent complexity. Objective This study aims to create an interpretable surrogate model for understanding a clinician's decision to perform AAA repair surgery. This was done by transforming complex machine learning (ML) outputs into a logistic regression framework using Shapley feature contributions, thereby increasing interpretability in clinical decision-making. Methods In a previous study, CT images were used to perform biomechanical and morphological analyses of AAA. The resulting dataset included various clinical variables (demographics, comorbidities, and pharmaceutical use). A total of 512 patients with either stable or repair outcomes were included in this study, with the training set (n = 410) and testing set (n = 102) split using an 80:20 ratio. Custom Python scripts were developed to train and evaluate logistic regression and ensemble boosted tree models on the dataset to classify repair outcomes from stable ones. Odds ratios were computed for the logistic regression, and Shapley Additive exPlanations values were calculated to interpret feature importance in the ensemble boosted tree model. Results The logistic regression model demonstrated an average cross-validation accuracy of 91% ± 3%, specificity of 77% ± 11%, sensitivity of 61% ± 11%, and an area under the receiver operating characteristics curve (AUROC) of 79% ± 5%. In comparison, the XGBoost model achieved an average accuracy of 95% ± 2%, specificity of 93% ± 7%, sensitivity of 74% ± 11%, and an AUROC of 86% ± 5%. Conclusions The utility of providing a probability for an event to occur can be potentially beneficial to clinicians based on the surrogate logistic function, as they are familiar with the risk score derived from odds ratios. The feature weights can be provided to promote a better understanding of which variables contribute to decision-making. Future work to understand clinicians' attitudes towards decision-support tools may lead to greater adoption of well-validated artificial intelligence tools.
No takes yet. Share an insight, caveat, or question.
Jeon et al. (2025) conducted an observational in Abdominal aortic aneurysm (AAA) (n=512). Ensemble boosted decision tree model (XGBoost) vs. Logistic regression model was evaluated on Classification accuracy for predicting stable vs. repair outcomes (p=<0.05). An ensemble boosted decision tree model combining clinical, biomechanical, and morphological data outperformed a standard logistic regression model in predicting abdominal aortic aneurysm repair outcomes, achieving an average accuracy of.