Key result
Abdominal aorta palpation by novice examiners significantly overestimated infrarenal aorta width compared to POCUS, with a mean difference of 0.97 cm (95% CI 0.67-1.26; P<0.001).
Why the study?
Palpation is traditionally used to screen for abdominal aorta aneurysm, but the agreement and reliability of abdominal aorta palpation compared to POCUS by novice physical therapy examiners was unknown.
Does abdominal aorta palpation accurately measure infrarenal abdominal aorta width compared to point of care ultrasound in healthy individuals?
Cross-Sectional (n=50)
Blinded to each other's findings
Randomized order
Does abdominal aorta palpation accurately measure infrarenal abdominal aorta width compared to point of care ultrasound in healthy individuals?
Mean Difference: 0.97 (95% CI 0.67–1.26)
Absolute Event Rate: 2.51% vs 1.54%
p-value: p=< .001
Palpation by novice examiners significantly overestimates abdominal aorta width compared to POCUS in healthy individuals, with accuracy decreasing as aorta size increases.
Novice palpation overestimates aortic width versus POCUS in healthy adults; leaves open its screening reliability in at-risk populations.
Purpose: Palpation is a traditional physical exam tool used to screen for abdominal aorta aneurysm. The purpose of this study was to determine agreement and reliability of abdominal aorta palpation measurements compared to point of care ultrasound (POCUS) measurements by novice physical therapy examiners in healthy individuals. Methods: Fifty healthy subjects over age 18 participated (age 25.2 ± 3.4). Two novice physical therapy examiners, blinded to each other's findings, measured infrarenal abdominal aorta width using a two-finger palpation technique and with POCUS, using a Vscan Air™ handheld ultrasound device, in randomized order. Bland–Altman analysis and paired t-tests compared agreement between palpation and POCUS measurements. Twenty-five participants returned within a month to assess intrarater reliability. Results: POCUS abdominal aorta width measurements averaged 1.54 cm (SD = 0.21), whereas palpation measurements averaged 2.51 cm (SD = 1.07), with a mean difference of 0.97 cm (SD = 1.03; 95% CI [0.67, 1.26]; P < .001). Palpation and POCUS measurements showed a positive correlation of 0.319 (P = .025); however, agreement decreased as aorta size increased. Intrarater reliability for POCUS had an intraclass correlation coefficient (ICC) of 0.58 (95% CI [0.25, 0.79]), and palpation showed intrarater reliability ICC of 0.59 (95% CI [0.25, 0.80]). Conclusions: Palpation overestimates infrarenal abdominal aorta width compared to POCUS in healthy individuals when performed by novice physical therapy examiners. While moderate agreement with POCUS exists, palpation accuracy decreases as aorta size increases, showing more variability. Further validation is needed in physical therapy examiners with more experience and in individuals with abdominal aortic aneurysm.
No takes yet. Share an insight, caveat, or question.
Calley et al. (2025) conducted a cross-sectional in Healthy individuals (n=50). Abdominal aorta palpation vs. Point of care ultrasound (POCUS) was evaluated on Infrarenal abdominal aorta width (MD 0.97, 95% CI 0.67, 1.26, p=< .001). Abdominal aorta palpation by novice examiners significantly overestimated infrarenal aorta width compared to POCUS, with a mean difference of 0.97 cm (95% CI 0.67-1.26; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: