Answers are grounded in this paper and cite their sources.
Light Detection And Ranging (LiDAR) systems have gained a great importance in today's wake characteristic measurements. The aim of this measurement campaign is to track the wake meandering and in a further step to validate the wind speed deficit in the meandering frame of reference (MFR) and in the fixed frame of reference using nacelle mounted LiDAR measurements. The measurement campaign has been prepared in detail by preliminary simulations mimicking the LiDAR behavior and corresponding wind field simulations. Additionally, a comparison between the modelled wake degradation in the MFR and the measured one could be conducted. The simulations were done with two different versions of the Dynamic Wake Meandering (DWM) model. These versions differ only in the description of the quasi-steady wake deficit. Based on the findings from the LiDAR measurements the formulation of the quasi-steady wake deficit in the DWM model has been adjusted, so that the recalibrated model coincides very well with the measurements.
No takes yet. Share an insight, caveat, or question.
Reinwardt et al. (2019) studied this question.