We demonstrate a high-pressure gas cell platform for the transmission electron microscope (TEM), scanning electron microscope (SEM), and X-ray synchrotrons. We extend the operable pressure range of these in-situ systems up to 30 bar, an over 10x improvement from the 1-2 bar limit of conventional in-situ cells. In-situ gas cell TEM has enabled investigation of morphological changes to nanoscale catalyst materials during gas exposure, revealing structure-property relationships and mechanisms affecting catalytic performance. On-chip heating and temperature sensing for in-situ sample holders have enabled highly localized specimen heating, improving heating time and sample stability up to >1000 °C for periods of hundreds of hours. Such experiments seek to reproduce the intended operational conditions for industrial catalyst systems, necessitating experimental pressures above 10 bar combined with temperatures of several hundred degrees for in-situ hardware. Gas cell operation far above atmospheric pressure was demonstrated using a novel in-situ gas TEM holder and custom microfabricated gas-heating cell. Burst pressures were determined in a high vacuum chamber by increasing the internal pressure until rupture. Operation of the holder was demonstrated in a Titan 80-300 Environmental TEM (ETEM) at the Center for Functional Nanomaterials at Brookhaven National Laboratory, wherein deliberately burst viewing windows were tested to ensure the differential pumping system could safely handle cell rupture and the escaping gas volume. Imaging and diffraction quality and stability were evaluated by TEM, dark-field (DF)-scanning transmission electron microscopy (STEM), and selected area electron diffraction (SAED) on cobalt nanoparticles (15-20 nm) and deposited platinum. Correlative analysis of 200 nm Co nanoparticle clusters was performed with scanning transmission X-Ray microscopy (STXM) at 20 bar O2 at the Advanced Light Source at Berkeley Lab. The chip membranes withstood up to 90 bar in the pump station rupture tests and the holder was successfully operated in the ETEM up to 30 bar to image cobalt nanoparticles and deposited Pt (see Figure 1). Resolution of ∼1.5 nm was achieved using deposited Pt islands at a broad range of pressures using dark-field (DF)-STEM, consistent with theory [1, 2]. Useful SAED patterns with distinguishable rings, shown in Figure 2, were also obtained at pressure for both the 15-20 nm Co nanoparticles and deposited Pt [3]. A greater sensitivity to contamination evolution under the electron beam was observed for elevated pressure and was ultimately the limiting factor in imaging resolution in these early experiments. This system will enable investigation of the morphological, microstructural, and microchemical evolution of heterogeneous CuZn catalysts at 10-20 bar of experimental gas and 200-300 °C. Although sample holder operation has been demonstrated up to 30 bar in the TEM, further qualification is needed to determine the appropriate maximum pressure rating for various imaging conditions and applications. Ultra-high purity gases are required to mitigate beam-induced contamination at high pressure, and long purge times at startup are recommended. The inclusion of on-chip heating elements combined with high-pressure gas will enable in-situ imaging of transformations in heterogenous catalysts under typical industrial process conditions. The strict drift, resolution, and vacuum requirements of the TEM make the gas cell also transferable to SEM and X-Ray synchrotron systems, enabling multi-modal investigation of catalyst evolution. The full high-pressure gas heating system for TEM, SEM and synchrotron chambers will enable full multi-modal and multiscale characterization of nanocatalyst evolution mechanisms in industrial applications [4]. Cobalt particles in DF-STEM at 10 bar N2 (left), physical vapor deposition (PVD) Pt in DF-STEM at 27.5 bar N2 (right). Cobalt particles in SAED at 3 bar N2 (left), PVD Pt in SAED at 13.8 bar N2 (middle), PVD Pt in SAED at 20.5 bar (right).
No takes yet. Share an insight, caveat, or question.
Hollyer et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: