Airway stenosis represents the commonest airway complication following lung transplantation, affecting between 7% and 18% of patients. Existing treatment options offer limited efficacy and can cause additional patient morbidity. Paclitaxel-coated balloons (PCB) have proved effective in managing postinterventional coronary artery re-stenosis. In a first-in-man study, we evaluated similar PCBs in refractory nonanastomotic airway stenosis in 12 patients. Following a single application, luminal patency was maintained in 50% at 270 days. No significant peri-interventional or early postinterventional complications occurred. Given these encouraging initial findings, further studies appear warranted.
No takes yet. Share an insight, caveat, or question.
Greer et al. (2014) studied this question.