Answers are grounded in this paper and cite their sources.
AIM: To investigate the relationship between intravascular ultrasound (IVUS) findings and restenosis after stent implantation for long occlusive femoropopliteal (FP) lesions using the intraluminal approach. METHODS: This was a single-center retrospective study of 45 patients (49 lesions) with de novo long occlusive FP lesions treated with bare metal stents implanted using the intraluminal approach under IVUS guidance from April 2007 to December 2014. All patients were followed up at least 12 months. The preprocedural and postprocedural IVUS findings were compared for patients with and without restenosis, which was defined as a peak systolic velocity ratio of >2.4 on duplex ultrasonography or >50% diameter stenosis on angiography. CONCLUSIONS: .
No takes yet. Share an insight, caveat, or question.
Mori et al. (2016) studied this question.