Key result
Intra-abdominal pressure of 15 mmHg during laparoscopic cholecystectomy decreased thoracic and lung static compliance by 49% and 39%, respectively, and increased end-tidal carbon dioxide.
Why the study?
Does carbon dioxide insufflation affect thoracic and lung compliance in patients undergoing laparoscopic cholecystectomies?
Observational (n=20)
Does carbon dioxide insufflation affect thoracic and lung compliance in patients undergoing laparoscopic cholecystectomies?
Carbon dioxide insufflation during laparoscopic cholecystectomy significantly decreases thoracic and lung compliance and increases end-tidal carbon dioxide.
Answers are grounded in this paper and cite their sources.
Anesthesiologists may need to adjust ventilation for reduced compliance during insufflation; hypothesis-generating for effects on outcomes.
Twenty patients having laparoscopic cholecystectomies were studied for changes in thoracic and lung compliance at 5, 10 and 15 mmHg of intra-abdominal pressure. Fifteen mmHg of intra-abdominal pressure decreased the thoracic and the lung static compliance by 49 and 39% respectively. This was unaffected by the degree of head elevation. During the procedure the end-tidal carbon dioxide increased by a mean of 1.6 kPa at 1 h and 2.0 kPa at 2 h. This did not appear to be related to either the mean intra-abdominal pressure or the total volume of carbon dioxide insufflated. The physiological changes and implications for anaesthetic practice are considered.
No takes yet. Share an insight, caveat, or question.
KENDALL et al. (1995) conducted an observational in Laparoscopic cholecystectomy (n=20). Carbon dioxide insufflation (intra-abdominal pressure) was evaluated on Changes in thoracic and lung compliance. Intra-abdominal pressure of 15 mmHg during laparoscopic cholecystectomy decreased thoracic and lung static compliance by 49% and 39%, respectively, and increased end-tidal carbon dioxide.
Synapse has enriched 10 related papers. Consider them for comparative context: