The power density and the efficiency of the actuators were characterized by simultaneously measuring the mechanical work performed and the electrical power applied. Maximum output power density was 0.93 kilowatt/kilogram, comparable with the best electric motors. At maximum power, the actuator was 60% efficient, but efficiencies were as high as 83% at lower power. Rotational actuators demonstrated a torque density of 79 newton meters/kilogram, substantially more than electric motors of comparable diameter. Scaling the droplet pitch from 100 to 48 micrometers increased power density from 0.27 to 0.93 kilowatt/kilogram, validating the quadratic scaling of actuator power.
No takes yet. Share an insight, caveat, or question.
Kedzierski et al. (2018) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: