Why the study?
The authors sought to summarize the experience and outcomes of total endovascular repair of thoracoabdominal aortic disease using 3D printed models to guide on-site creation of fenestrations in aortic stent-grafts.
Does the use of 3D printed models to guide fenestration in physician-modified stent-grafts allow safe and effective treatment in patients with thoracoabdominal aortic disease?
Does the use of 3D printed models to guide fenestration in physician-modified stent-grafts allow safe and effective treatment in patients with thoracoabdominal aortic disease?
Using 3D printed models to guide the creation of fenestrated stent-grafts is a feasible and safe technique for treating thoracoabdominal aortic diseases involving crucial branches.
Answers are grounded in this paper and cite their sources.
Physician-modified fenestrated grafts guided by 3D models appear feasible for thoracoabdominal disease; leaves open need for prospective validation before wider adoption.
Purpose: To summarize the experience and outcomes of total endovascular repair of thoracoabdominal aortic disease using 3-dimensional (3D) printed models to guide on-site creation of fenestrations in aortic stent-grafts. Materials and Methods: From April 2018 to March 2019, 34 patients (mean age 58±14 years; 24 men) with thoracoabdominal aortic disease were treated in our department. Nineteen patients had thoracoabdominal aortic dissection and 15 had thoracoabdominal aortic aneurysm. Preoperatively, a 3D printed model of the aorta was made according to computed tomography images. In the operating room, the main aortic stent-graft was completely released in the 3D printed model, and the position of each fenestration or branch was marked on the stent-graft. The fenestrations were then made using an electric pen. Wires were sewn to the edge of the fenestrations using nonabsorbable sutures. After customization, the aortic stent-graft was reloaded into the delivery sheath and deployed. Results: The printing process took ~5 hours (1 hour for image reconstruction, 3 hours for printing, and 1 hour for postprocessing). The physician-modified stent-grafts had a total of 107 fenestrations secured by 102 bridging stent-grafts, including 73 covered stents and 29 bare stents. The average procedure time was 5.6±1.2 hours, including a mean 1.3 hours for stent-graft customization. No renal insufficiency or paraplegia occurred. Two branch arteries were lost during the operation. One patient (3%) died 1 week after surgery from a retrograde dissection rupture. One patient developed a minor cerebral infarction postoperatively. The mean follow-up time was 8.5 months. There was 1 endoleak from a fenestration (coil embolized) and 4 distal ruptures of the aortic dissection (3 treated and 1 observed). Conclusion: Three-dimensional printing can be used to guide creation of fenestrated stent-grafts for the treatment of thoracoabdominal aortic diseases involving crucial branches. This technique appears to be more accurate than the traditional measurement method, with short-term follow-up demonstrating the safety and reliability of the method. However, further research and development are needed.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: