The diffusion coefficient of particles 5 to 8 A in diameter primary radon daughters, for instanceis roughly 100 times that for condensation nuclei (200 to 1000 A in diameter) to which radon daughters normally attach. This difference should manifest itself as a measurable increase in daughter deposition on uranium mine walls were condensation nuclei previously removed by air filtration. This report is an account of experiments done to quantify the degree to which this simple air treatment might make a mine atmosphere self-ridding of radon daughters. Experimental results indicate that airborne RaA can be kept to less than 50% and RaC taken to less than 30% of concentrations they would grow to otherwise. Practical applications are not immediately obvious. However, in time and with engineering ingenuity the power of the filtration technique may be brought to bear on secondary ventilation problems.