Key result
Concept-based ECG explanations show directional instability across models, with ~44% exhibiting significant reversals.
Why the study?
Fewer studies examine whether AI explanation methods are stable across independently trained copies of the same model.
Statistical significance and confound robustness alone do not guarantee that a concept-based AI explanation for ECG interpretation is stable across independently trained models.
Instability in CAV explanations for AF detection models urges caution in clinical interpretability; leaves open whether seed-level checks can ensure reliability.
AI explanation methods are typically validated in one of two ways: by confirming that an explanation is not an artifact of the underlying data (a confound check), or by confirming that it generalizes to unseen data. Fewer studies examine whether an explanation is stable across independently trained copies of the same model. We present a validation framework combining both dimensions — confound control and model-seed reproducibility — and demonstrate it in a case study using a deep learning model trained to detect atrial fibrillation (AF) from long, continuous ECG recordings. Using concept activation vectors (CAVs), we test whether the model's predictions are associated with three clinically meaningful patterns: irregular heartbeat timing, the presence of abnormal beats, and proximity to a rhythm change. We find that a concept-prediction association can be statistically significant and survive a targeted AF-label confound control in one trained model, yet reverse direction when the same architecture is retrained from a different random initialization. Across the nine concept-depth combinations examined, three replicated consistently across five independently trained models, two were inconclusive, and four showed evidence of directional instability under the predefined criterion. These findings demonstrate, within this AFNet/LTAFDB case study, that statistical significance and confound robustness alone may not establish a stable concept-based explanation; model-seed reproducibility provides a complementary validation dimension that can reveal sensitivity to training initialization.
No takes yet. Share an insight, caveat, or question.
Jennah et al. (2026) studied Atrial Fibrillation (n=84). Testing with Concept Activation Vectors (TCAV) was evaluated on Directional stability of concept-prediction association across 5 independently trained models. Concept-based ECG explanations (TCAV) showed directional instability across independently trained models, with 4 of 9 concept-depth combinations exhibiting significant reversals despite surviving confound controls.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: