Key result
Simulated sinus rhythm restoration expels ~50% of clot vs persistent AF via increased shear strain.
Why the study?
The impact of recovered atrial dynamics on pre-existing left atrial appendage thrombi after sinus rhythm restoration in atrial fibrillation is poorly understood.
Does sinus rhythm restoration alter thrombus behaviour and haemodynamics in the left atrial appendage compared to persistent atrial fibrillation?
Does sinus rhythm restoration alter thrombus behaviour and haemodynamics in the left atrial appendage compared to persistent atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Computational modeling demonstrates that restoration of sinus rhythm increases local shear strain rates in the LAA, promoting thrombus erosion and detachment compared to persistent AF, providing a mechanistic explanation for the clinical risk of embolization following cardioversion.
The impact of recovered atrial dynamics on pre-existing thrombi within the left atrial appendage (LAA) remains a poorly understood phenomenon, despite its potential clinical implications during spontaneous or induced restoration of sinus rhythm (SR) in patients with atrial fibrillation (AF). While computational studies have investigated thrombus formation during AF, none have examined the fate of established thrombi following SR restoration. This work addresses that gap by modelling thrombus formation and embolisation in the LAA under AF and after the return to normal rhythm. A meshless particle-based thrombus model was employed to simulate the formation of clots in a patient specific LAA, under AF conditions, and then analyse haemodynamic changes and thrombus behaviour under persistent AF and recovered SR. Results show that SR restoration profoundly modifies thrombus growth and erosion compared with AF. The resumption of atrial contractility increases local shear strain rate, especially in the proximity of anatomical features such as knees and trabeculae, driving progressive thrombi erosion and detachment from secondary lobes. These processes are amplified during the atrial systolic phase, when mechanical forces promote thrombus detachment. Conversely, if AF persists, the associated reduction in blood wash-out and shear stresses promote thrombus growth. Clots located in regions of higher stagnation remain stable under both restored SR and persistent AF. By providing the first direct computational comparison of thrombus behaviour in AF and after SR restoration, this work offers novel insights with potential to inform personalised therapeutic strategies.
No takes yet. Share an insight, caveat, or question.
Presti et al. (2026) studied Atrial fibrillation (n=1). Sinus rhythm restoration (simulated) vs. Persistent atrial fibrillation (simulated) was evaluated on Thrombus erosion and detachment (percentage of solid particles). Simulated sinus rhythm restoration increased local shear strain rates up to 40 s-1, resulting in the expulsion of approximately 50% of the clot within the first six cycles compared to persistent AF.
Synapse has enriched 10 related papers. Consider them for comparative context: