Answers are grounded in this paper and cite their sources.
Experimental and modeling study demonstrates thermal efficiency exceeding 55% in pillow-plate air collectors, highlighting potential for low-temperature heating applications.
This work presents the theoretical and experimental analysis of a novel air – based flat plate collector using pillow – plate (PP) geometry. The proposed design aims to enhance the heat transfer when using air as heat transfer fluid. A prototype was tested under outdoor conditions for airflow rates between 50 and 350 L/min and three internal flow configurations (H, U and Z), and a steady – state model based on the Hottel – Whillier approach was developed and validated. Results on temperature pattern distribution show that airflow rate dominates thermal performance. Efficiency increases with flow rate, exceeding 55 % for the H configuration, while temperature rise decreases, reaching up to 35 °C at low flow rates, corresponding to normalized temperature – rise values (ΔT/ A c ) above 200 °C/m 2 at airflow rates close to 50 L/min. The U configuration provides more uniform thermal behaviour, whereas the H configuration achieves the highest efficiencies. In addition, the steady − state model reproduced the experimental results with deviations generally within ± 10 % at intermediate and high airflow rates. The PP – based collector demonstrates competitive performance compared to conventional systems, highlighting its potential for low – temperature industrial and heating, ventilation and air conditioning applications.
No takes yet. Share an insight, caveat, or question.
Cánovas–Cabrera et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: