Key result
In asymmetric double-orifice mitral valve repair, the difference in mean pressure gradient between orifices was statistically significant (1.04 mm Hg, P<0.0001) but not clinically relevant.
Why the study?
Does Doppler echocardiography of either orifice reliably determine pressure gradients in patients undergoing asymmetric double-orifice mitral valve repair?
Observational (n=15)
Does Doppler echocardiography of either orifice reliably determine pressure gradients in patients undergoing asymmetric double-orifice mitral valve repair?
Either orifice can be interrogated with Doppler echocardiography for the determination of pressure gradients after double-orifice mitral valve repair, as differences in mean transorifice pressure gradients between asymmetric orifices are not clinically relevant.
Answers are grounded in this paper and cite their sources.
Supports Doppler interrogation of either orifice for gradients after asymmetric double-orifice repair; leaves open prospective confirmation in larger cohorts.
BACKGROUND: A comprehensive transesophageal echocardiographic (TEE) examination is essential for the evaluation of a mitral valve (MV) repair. The edge-to-edge MV repair (i.e., Alfieri stitch) can pose a unique challenge in assessing iatrogenic mitral stenosis, especially when an asymmetric double-orifice is created. The reliability of the simplified Bernoulli equation for evaluating transvalvular pressure gradients across an asymmetric Alfieri MV repair remains controversial. We sought to evaluate the reliability of this principle further by comparing TEE-acquired pressure gradients across each orifice in patients undergoing asymmetric, double-orifice repair. METHODS: Routinely collected intraoperative, 2-dimensional and 3-dimensional TEE datasets acquired from 15 patients undergoing double-orifice MV repair were retrospectively reviewed and analyzed. Planimetered anterior lateral (AL) and posterior medial (PM) orifice areas were acquired from 3-dimensional TEE full volume datasets, by cropping the image to develop a short-axis view at the narrowest diastolic orifice cross-sectional area at the MV leaflet tips. Transmitral Doppler flow velocity values were measured through the AL and PM orifices. Peak and mean pressure gradients were calculated from the simplified Bernoulli equation at both orifices and were compared to each respective orifice for each patient. RESULTS: The mean difference between the AL and PM orifice areas for each patient was statistically significant (0.72 ± 0.40 cm(2), P < 0.0001). The mean differences between the AL and PM parameters were also significant for peak velocity: 0.15 m/s, SD: 0.08, P < 0.0001; peak pressure gradients: 1.76 mm Hg, SD: 1.42, P < 0.0001; and mean pressure gradient: 1.04 mm Hg, SD: 0.93, P < 0.0001. CONCLUSIONS: The echocardiographic assessment of MV dysfunction after an Alfieri repair is important. Although the differences that we demonstrated between orifice areas and maximum velocities across the asymmetric orifices after a double-orifice MV repair are statistically significant, the corresponding difference in mean transorifice pressure gradient is not clinically relevant. Thus, either orifice can be interrogated with Doppler echocardiography for the determination of pressure gradients after double-orifice MV repair.
No takes yet. Share an insight, caveat, or question.
Trzcinka et al. (2014) conducted an observational in Asymmetric double-orifice mitral valve repair (n=15). Anterior lateral (AL) orifice vs. Posterior medial (PM) orifice was evaluated on Mean pressure gradient (MD 1.04 mm Hg, p=< 0.0001). In asymmetric double-orifice mitral valve repair, the difference in mean pressure gradient between orifices was statistically significant (1.04 mm Hg, P<0.0001) but not clinically relevant.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: