Key result
Transthoracic echocardiography was used to guide MitraClip implantation in a patient with poor transoesophageal echocardiographic image quality.
Why the study?
Can transthoracic echocardiography be used to guide MitraClip implantation when transoesophageal echocardiography images are of poor quality?
Case Report (n=1)
Can transthoracic echocardiography be used to guide MitraClip implantation when transoesophageal echocardiography images are of poor quality?
Answers are grounded in this paper and cite their sources.
Transthoracic echocardiography can serve as an alternative imaging modality for guiding MitraClip implantation when transoesophageal echocardiography is inadequate.
BACKGROUND: A 71-year-old woman affected by idiopathic dilated cardiomyopathy with normal coronary arteries and permanent atrial fibrillation was found to have severe mitral regurgitation at transthoracic echocardiography (TTE), due to annular dilatation and restricted motion of the posterior leaflet. Because of poor quality of life, high functional class (NYHA Class III) and the high risk of surgery, the patient agreed to undergo the implantation of a MitraClip device. During the procedure, the transoesophageal echocardiographic (TEE) images were of a poor quality since the view of the mitral valve in the mid-oesophageal and transgastric projections did not accurately show the valve leaflets and the convergence area of the regurgitation at colour Doppler, which is indispensable for the correct positioning of the clip. INVESTIGATION: Physical examination, transthoracic echocardiography, transoesophageal echocardiography. DIAGNOSIS: Severe mitral regurgitation suitable for MitraClip implantation. MANAGEMENT: Transthoracic, and not transoesophageal, echocardiography approach during MitraClip procedure.
No takes yet. Share an insight, caveat, or question.
Duino et al. (2014) conducted a case report in Severe mitral regurgitation (n=1). MitraClip implantation guided by transthoracic echocardiography was evaluated. Transthoracic echocardiography was used to guide MitraClip implantation in a patient with poor transoesophageal echocardiographic image quality.
Synapse has enriched 10 related papers. Consider them for comparative context: