Key result
A preoperative sinus of Valsalva diameter >40 mm strongly predicted the presence of a plicature-indicating leaflet prolapse.
Why the study?
Aortic leaflet prolapse in aortic root replacement is linked to advanced pathology, making it important to identify parameters to perform root replacement before prolapse reaches its maximum extent.
Do preoperative aortic root dimensions predict the need for cusp plication for leaflet prolapse in patients undergoing aortic valve-sparing root replacement?
Cohort (n=39)
Do preoperative aortic root dimensions predict the need for cusp plication for leaflet prolapse in patients undergoing aortic valve-sparing root replacement?
A sinus of Valsalva diameter >40 mm strongly predicts the presence of leaflet prolapse requiring plication, suggesting root repair should be considered before dilatation reaches this extent.
Answers are grounded in this paper and cite their sources.
May inform root repair timing; leaves open prospective validation for plication prediction in valve-sparing surgery.
BACKGROUND: In aortic root replacement, "preexisting" or "induced" aortic leaflet prolapse is related to advanced aortic root pathology and can indicate valve repair. Efforts should be made to perform root replacement before leaflet prolapse is in its maximum extent. MATERIALS AND METHODS: Thirty-nine patients with chronic aortic root dilatation and aortic valve regurgitation (AR) underwent a reimplantation procedure. Contrary to 32 of the 39 patients (group A), 7 of the 39 patients (group B) underwent cusp plication for prolapse. For both groups, data related to the diameter at the level of maximal tubular extension, sinotubular junction, sinus of Valsalva, aorto-ventricular junction (AVJ), and aortic annulus were obtained from preoperative computed tomography scans and analyzed comparatively. RESULTS: Group B showed a higher mean AR grade (P = .007), a higher mean diameter at the level of the aortic annulus (P = .038), AVJ (P = .037), and aortic sinus (P <.001) and a higher sinus dilatation index (existing-to-predicted diameter ratio) (P <.001) than group A. The sinus of Valsalva displayed the best predictive value regarding a plicature-indicating prolapse (P <.001; 95% confidence interval [CI]: 0.809-1.013). A diameter >40 mm was accompanied by an odds ratio (OR) of 24.6 (95% CI: 1.29-496.02). During the follow-up period of 29.0 ± 18.4 months (range: 6-62 months), 1 patient (group A) required reoperation 5 years postoperatively for progressive AR. CONCLUSION: The sinus of Valsalva diameter seems to have the greatest prognostic value for the development of prolapse. Our data suggest that root repair should be considered earlier in time before leaflet prolapse is complete, which most likely occurs when root dilatation becomes an aneurysm.
No takes yet. Share an insight, caveat, or question.
Borowski et al. (2019) conducted a cohort in Chronic aortic root dilatation and aortic valve regurgitation (n=39). Sinus of Valsalva diameter >40 mm vs. Sinus of Valsalva diameter ≤40 mm was evaluated on Plicature-indicating prolapse (OR 24.6, 95% CI 1.29-496.02, p=<.001). A preoperative sinus of Valsalva diameter >40 mm strongly predicted the presence of a plicature-indicating leaflet prolapse.