Aerococcus urinae bacteremia can cause cardiac implanted electronic device infections, as demonstrated in an 84-year-old male who required complete pacemaker removal and antibiotics for recovery.
Case Report (n=1)
This case report demonstrates that Aerococcus urinae can cause cardiac implanted electronic device (CIED) infections, highlighting the need to consider this risk in patients with A. urinae bacteremia and a CIED.
Answers are grounded in this paper and cite their sources.
Consider A. urinae in CIED patients with bacteremia; extends known pathogens but remains hypothesis-generating.
Background. Aerococcus urinae has lately been acknowledged as a cause of infective endocarditis (IE) especially in older males with underlying urinary tract disorders. In this population, cardiac implanted electronical devices (CIED) are not uncommon, but despite the capacity of A. urinae to form biofilm in vitro, no cases of aerococcal CIED infections have been reported to date. Case Presentation. An 84-year-old male with pacemaker was admitted with dysuria one month after a transurethral procedure for urinary bladder cancer. A. urinae was isolated from urine and blood. Transesophageal echocardiography (TEE) was without signs of vegetation on valves or pacing cables. The patient was treated with a twelve-day course of β-lactam antibiotics. Forty days after the initial admission, the patient was readmitted due to malaise, general pain of the joints, chills, and renewed blood cultures grew A. urinae. TEE demonstrated a 10 × 5 mm vegetation on either the tricuspid valve or one of the pacing cables. The pacemaker system was completely removed and demonstrated macroscopic signs of infection. A temporary system was implanted, and after 14 days of penicillin G treatment, a new system permanent system was implanted. Total treatment time was 40 days. Recovery was uneventful. Conclusion. This report demonstrates that A. urinae can cause CIED infection. In patients with A. urinae bacteremia and a CIED, this risk must be considered, especially if bacteremia reoccurs.
No takes yet. Share an insight, caveat, or question.
Samuelsson et al. (2018) conducted a case report in Pacemaker endocarditis (n=1). Aerococcus urinae infection was evaluated on Recovery from CIED infection. Aerococcus urinae bacteremia can cause cardiac implanted electronic device infections, as demonstrated in an 84-year-old male who required complete pacemaker removal and antibiotics for recovery.